In animal experiments, it is often necessary to perform
microinjection on animals. An automatic microinjection pump is used,
which is convenient to use. The syringe of the injector is installed on
the injection pump and connected to the gripper through a conduit. The
precise movement of the injector piston is controlled by a microcomputer
to drive the unit, achieving injection or recovery of liquids in
experimental animals and leaving more operating space for the
experiment.
M5261 dual channel microinjection pump, high-definition
touch screen operation, Ditronstep micro step control system, used for
precise control and delivery of trace liquid drugs or solutions. It is
usually used in conjunction with brain locators or microcontrollers in
the medical field, especially in clinical medicine, laboratory research,
and drug development. This injection pump is compatible with most
imported and domestic microinjectors (0.5ul-100ml), with a stroke
resolution of 0.0625 μ m/μ step, a linear velocity range of 0.08 μ m/min
to 160mm/min (flow rate=linear velocity x syringe loading area), and a
propulsion distance of 150mm.
Functional Features
1. Working mode: infusion, extraction, infusion/extraction, extraction/infusion, continuous, multiple infusion
2. Touch display: 5-inch high-definition touch screen, simple, clear, easy to understand, and controllable
3. Language types: Chinese and English, 2 languages to choose from
4. Online speed regulation: adjust the current flow rate without stopping the machine during operation
5. Calibration function: Supports syringe calibration and stores calibration parameters
6.
Syringe selection: Built in from major domestic and foreign
manufacturers, with a choice of main models of syringes and support for
customization
7. Parameter settings: Liquid volume, flow rate,
infusion time, extraction time, interval time, and infusion frequency
can be set and stored
8. Power on operation: Store the current
dynamic operating parameters when powered off, and resume operation
after powering on again
9. Reminder function: Real time display of available Max/Min flow rate; Dynamically display operating parameters
10. Reminder function: Run to the set target liquid volume, sound alarm prompt
11. Thrust setting: Suitable thrust can be set according to the specifications of each injector
12. External control function: external level or pulse signal to achieve start stop control
13. Communication control: RS485/USB optional, touch settings for address and baud rate
14. Status output: start stop, direction status output
Technical Parameter
1. Number of channels: Dual channels
2. Working mode: infusion, extraction, infusion/extraction, extraction/infusion, continuous, multiple infusion
3. Maximum travel: 150mm
4. Accuracy:<1%
5. Repetitive accuracy: Error ≤ ± 0.05%
6. Sample injector specifications: 0.5 μ L to 100mL
7. Linear thrust: ≥ 160N
8. Linear speed range: 0.08 μ m/min to 160mm/min
Step resolution: 0.0625 μ m/μ step
10. Applicable power supply: AC 100V~240V 50/60Hz 30W
11. Working environment: Temperature: 0-40 ℃ Humidity: Humidity 20% -80% RH No condensation
12. Storage environment: Temperature: -10~60 ℃ Humidity: Humidity: 20% -80% RH No condensation
13. Protection level: IP31
14. Product size (mm): 256 * 190 * 146 (mm)
Applicable Syringes
Optional syringe capacity | Inner diameter of syringe(mm) | Reference flow range(nL/min-mL/min) | Optional syringe capacity | Inner diameter of syringe(mm) | Reference flow range(nL/min-mL/min) |
0.5ul | 0.103 | 0.0007~0.0013 | 500ul | 3.256 | 0.6658~1.3322 |
1ul | 0.146 | 0.0013~0.0027 | 1ml | 4.73 | 1.4060~2.8110 |
2ul | 0.206 | 0.0027~0.0053 | 2ml | 8.92 | 4.9990~9.9980 |
5ul | 0.343 | 0.0074~0.0148 | 2.5ml | 8.92 | 4.9990~9.9980 |
10ul | 0.485 | 0.0148~0.0295 | 5ml | 12.4 | 9.6620~19.3220 |
25ul | 0.729 | 0.0334~0.0668 | 10ml | 14.87 | 13.8940~27.7860 |
50ul | 1.03 | 0.0667~0.1333 | 20ml | 19.07 | 22.8500~45.6990 |
100ul | 1.457 | 0.1334~0.2668 | 50ml | 28.95 | 52.6600~105.3190 |
250ul | 2.304 | 0.3335~0.6671 | 60ml | 29.47 | 54.5680~109.1360 |
Ordering Information
Model | Name | Trip(mm) |
M5126 | Manual microinjection pump | 0-25 |
M5136 | Manual microinjection pump | 0-50 |
M5258 | High precision microinjection pump | 0-70 |
M5259 | Dual channel high-precision microinjection pump | 0-70 |
M5260 | Microinjection pump | 0-150 |
M5261 | Dual channel microinjection pump | 0-150 |
M5262 | Four channel microinjection pump | 0-150 |
M5263 | Ultra precision microinjection pump | 0-150 |
M5264 | Dual channel independent control microinjection pump | 0-150 |
Selection Guide
M5136 Manual microinjection pump | M5258 High precision microinjection pump | M5259 Dual channel high-precision microinjection pump | M5260 Microinjection pump |
M5261 Dual channel microinjection pump | M5262 Four channel microinjection pump | M5263 Ultra precision microinjection pump | M5264 Dual channel independent control microinjection pump |